Annual Inspections
We are committed to conducting over 8,000 annual inspections in the city of Torrance. These inspections also include our new businesses. We strive to provide quality inspection service to our community which is part of Our Mission to provide life safety services and reduce hazards.same time we can educate people about the value of fire sprinklers, maintaining exits, and other fire safety features of their environment.
Different areas of Torrance are handled by different inspectors. To see which inspector is assigned to your area, please refer to the following map:
If the building is a high-rise, four stories or above, it must be inspected by the senior fire investigator or the senior fire prevention officer.
5 Year Testing on Sprinkler Systems
The following guideline shall be referenced as the standard operating procedure to conduct five-year tests of fire sprinkler systems. Only buildings with an NFPA 13 or NFPA 13R system are covered by this guideline; it does not apply to buildings with an NFPA 13D system.
Additional most up-to-date forms are on the OSFM website under the Automatic Extinguishing System, forms, labels and tags:
http://osfm.fire.ca.gov : Go to Engineering, then click on Automatic Extinguishing System, Then click on Forms, Labels, and Tags
Automatic Extinguishing System Forms, Labels, and Tags
Water-Based Fire Suppression System Label
Fixed Engineered and Pre-Engineered Fire Suppression System Tag
AES 1 Inspection, Testing, Maintenance Cover Sheet
AES 2.1 Wet Pipe Fire Sprinkler System Quarterly/Annual
AES 2.2 Wet Pipe Fire Sprinkler System Five Year
AES 2.3 Dry Pipe Fire Sprinkler System Quarterly/Annual
AES 2.4 Dry Pipe Fire Sprinkler System Five Year
AES 2.5 Pre-action Sprinkler Systems Quarterly/Annual
AES 2.6 Pre-action Sprinkler Systems Water Five Year
AES 2.7 Deluge Sprinkler Systems Water Spray Quarterly/Annual
AES 2.8 Deluge Sprinkler Systems Water Spray Five Year
AES 2.9 Main Drain Test Continuation Form
AES 3 Standpipe and Hose Systems
AES 3.1 Standpipe and Hose System Five Year
AES 4 Private Fire Service Mains
AES 4.1 Private Fire Service Main
AES 5.1 Diesel Fire Pump Weekly
AES 5.2 Diesel Fire Pump Annual
AES 5.3 Electric Fire Pump Monthly
AES 5.4 Electric Fire Pump Annual
AES 7 Water Spray Fixed Systems
AES 8 Foam-Water Sprinkler Systems
AES 10 Corrective Action and Repairs Performed
AES 11 Limited License Tool Checklist
AES 12 Local Fire Authority Endorsement
AES 20 Wet Chemical Pre-Engineered Fire Extinguishing System;Semi-Annual
AES 21 Dry Chemical Pre-Engineered Fire Extinguishing System- Semi-Annual
AES 22 Specialty Pre-Engineered and Engineered Fire Extinguishing System - Semi-Annual